SCA_DelaySensor(SCA_ISensor)

base class — SCA_ISensor

class bge.types.SCA_DelaySensor

The Delay sensor generates positive and negative triggers at precise time, expressed in number of frames. The delay parameter defines the length of the initial OFF period. A positive trigger is generated at the end of this period.

The duration parameter defines the length of the ON period following the OFF period. There is a negative trigger at the end of the ON period. If duration is 0, the sensor stays ON and there is no negative trigger.

The sensor runs the OFF-ON cycle once unless the repeat option is set: the OFF-ON cycle repeats indefinitely (or the OFF cycle if duration is 0).

Use SCA_ISensor.reset at any time to restart sensor.

delay

length of the initial OFF period as number of frame, 0 for immediate trigger.

Type:

integer.

duration

length of the ON period in number of frame after the initial OFF period.

If duration is greater than 0, a negative trigger is sent at the end of the ON pulse.

Type:

integer

repeat

1 if the OFF-ON cycle should be repeated indefinitely, 0 if it should run once.

Type: